1. Deactivate the detector. On a clean surface, place the
detector face down.
2. Remove the six machine screws from the rear shell.
Remove the back cover by lifting the top and the
bottom upwards simultaneously to prevent damaging
the charging pins.
Replacing the sensor filter
1. Note the placement of the PCB to ensure it is
replaced correctly. Remove the two screws on the
PCB. Remove the PCB carefully.
a
Caution
Ensure no damage occurs to the battery.
2. Remove the old sensor filter. It may be stuck to the
sensors.
3. Place the new sensor filter.
Note
When inserting a new sensor filter, ensure the black
gasket is facing the front shell.
4. To complete the detector, refer to Reassembling the
detector.
Item Description Item Description Item Description
1 Front shell 5 Rear shell 9 H
2
S sensor
2 LEL sensor 6 Machine screws (6) 10 O
2
sensor
3 PCB 7 Sealing rib 11 Sensor filter
4 PCB screws (2) 8 CO sensor
1
11
10
3
2
4
6
5
8
9
7