User ManualGasAlertMicroClip1, 2, 3, and 4 Gas Detectors D5908/2 EnglishiERP: 124291© BW Technologies 2007, all rights reserved. Printed in Canada.A
GasAlertMicroClip User Manual Contacting BW Technologies by Honeywell To contact BW Technologies by Honeywell, call: USA: 1-888-749-8878 Canada: 1-800
GasAlertMicroClip Safety Information - Read First aCautions⇒ Warning: Substitution of components may impair Intrinsic Safety. ⇒ Caution: For saf
GasAlertMicroClip User Manual aCautions⇒ Protect the combustible sensor from exposure to lead compounds, silicones, and chlorinated hydrocarbons. Alt
GasAlertMicroClip Safety Information - Read First Table 2. International Symbols Symbol Meaning nApproved to both U.S. and Canadian Standards by C
GasAlertMicroClip User Manual Getting Started The list below provides the standard items included with your detector. If the detector is damaged or so
GasAlertMicroClip Getting Started Figure 1. Parts of the GasAlertMicroClip Table 3. Parts of the GasAlertMicroClip Item Description 1 Visual ala
GasAlertMicroClip User Manual Table 4. Display Elements Item Description 1 Alarm condition 2 Automatically span sensor 3 Gas cylinder 4 Gas identifie
GasAlertMicroClip Getting Started Table 5. Pushbutton Pushbutton Description C• To activate the detector press C. • To deactivate the detector,
GasAlertMicroClip User Manual Activating the Detector To activate the detector, press C in a normal clean atmosphere. Self-Test Once the detector is a
GasAlertMicroClip Activating the Detector Note Users can enter a 2-line message, up to a maximum of 25 characters per line. The messag
Limited Warranty & Limitation of Liability BW Technologies LP (BW) warrants this product to be free from defects in material and workmanship under
GasAlertMicroClip User Manual Note The sensors are continuously tested while the detector is activated. Automatic Zero and O2 Calibration (optional) 5
GasAlertMicroClip Activating the Detector Press C to acknowledge the warning and enter normal operation, or continue with the self-test if appli
GasAlertMicroClip User Manual Bump Check (optional) Note Bump check is not performed if the detector was just calibrated (step #6). BW recommends to “
GasAlertMicroClip Activating the Detector Self-Test Fail While the LCD displays BUMPCHK todAY, apply gas to the detector or press C to deactivate
GasAlertMicroClip User Manual Backlight The LCD’s backlight automatically activates when there is an alarm condition. Pressing C activates the backlig
GasAlertMicroClip Options Sensor Disabled Detector Identification a Warning Start-up Message Disabling an installed sensor configures the detector
GasAlertMicroClip User Manual Bump Interval Calibration Gas Concentration The Bump Interval determines the number of days before a sensor needs to be
GasAlertMicroClip Options Automatic O2 Calibration TWA Alarm When the O2 Auto-Calibration on Startup option is enabled, it forces the detector to a
GasAlertMicroClip User Manual User Options Menu Confidence Beep The Confidence Beep notifies that the detector is on and the battery has sufficient po
GasAlertMicroClip Options Low Alarm Acknowledge Force Bump When Overdue When Low Alarm Acknowledge is enabled, the audible alarm can be disabled du
Table of Contents Title Page Introduction...
GasAlertMicroClip User Manual If more than one type or level of alarm exists at the same time, a multi-gas alarm will result. Alarms The following tab
GasAlertMicroClip Alarms Table 6. Alarms Alarms Display Alarms Display Multi-Gas Alarm: • Alternating low and high alarm siren and flash • L and t
GasAlertMicroClip User Manual Table 6. Alarms Alarms Display Normal Shutdown: • Four beeps and flashes • Vibrator alarm temporarily activates Note
GasAlertMicroClip Alarms Viewing Gas Exposures To view the TWA, STEL, and maximum (MAX) hold readings, press C twice. The LCD first displays the TW
GasAlertMicroClip User Manual Gas Alarm Setpoints The detector's gas alarm setpoints trigger the gas alarms that are described in the table below
GasAlertMicroClip Alarms Stopping a Gas Alarm The low and high alarms stop when the ambient gas level returns to the acceptable range. Note If alar
GasAlertMicroClip User Manual Calibration • Calibrate the detector at least once every 180 days, depending on use and sensor exposure to poisons and
GasAlertMicroClip Calibration Wind currents may cause false readings and poor calibrations. Diagnostics Protection The detector tests the ambient a
GasAlertMicroClip User Manual Calibration Procedure To calibrate the detector perform the following procedure. Note Calibrate O2 in clean air. If C is
GasAlertMicroClip Calibration Auto Zero and Oxygen Sensor Calibration Auto Span 4. The LCD now prompts you to apply calibration gas to the sensors
GasAlertMicroClip User Manual ii Title PageLow Battery Alarm ...
GasAlertMicroClip User Manual No Gas Detected When the detector senses a sufficient amount of gas concentration (approximately 30 seconds), the audibl
GasAlertMicroClip Calibration If you apply gas to a sensor and the detector fails to span the sensor, repeat the calibration procedure using a new
GasAlertMicroClip User Manual Verification • Peak exposure level (ppm or %); After calibration is complete and the detector is in normal operating mo
GasAlertMicroClip Maintenance Charging the Detector a Warning ⇒ The detector must be charged in a non-hazardous atmosphere of 32°F - 113°F (0°C -
GasAlertMicroClip User Manual Each sensor has a high degree of resistance to common vapors and gases. A sensor will most likely clear itself if you mo
GasAlertMicroClip Maintenance 3. Remove the two screws on the PCB and remove the PCB. Table 11. Replacing a Sensor or Sensor Filter Item Descripti
GasAlertMicroClip User Manual 6. Re-assemble the detector. When assembling the detector, be aware of the following: • Ensure the charging contact pi
GasAlertMicroClip Troubleshooting Troubleshooting If you are still unable to correct the problem, contact BW Technologies by Honeywell. The detect
GasAlertMicroClip User Manual Table 12. Troubleshooting Tips (cont.) Problem Possible Cause Solution Detector does not display normal ambient gas read
GasAlertMicroClip Troubleshooting Table 12. Troubleshooting Tips (cont.) Problem Possible Cause Solution Detector does not enter alarm. → Alarm se
List of Tables Table Title Page 1. Gases Monitored ...
GasAlertMicroClip User Manual Replacement Parts and Accessories a Warning To avoid personal injury or damage to the detector, use only the specified r
GasAlertMicroClip Specifications Model No. Description Qty MC-VC-K1 Vehicle charging kit 1 MC-C01-MC5*GasAlertMicroClip MultiCharger 1 GA-USB1-
GasAlertMicroClip User Manual Approvals: Approved by CSA to both U.S. and Canadian Standards CAN/CSA C22.2 No. 157 and C22.2 152 ANS/UL – 913 and ANSI
GasAlertMicroClip Specifications General Datalogger Specifications Storage: 16 hours at 15-second intervals Memory type: Wraparound memory ensures
GasAlertMicroClip User Manual 46
User ManualGasAlertMicroClip1, 2, 3, and 4 Gas Detectors D5908/2 EnglishiERP: 124291© BW Technologies 2007, all rights reserved. Printed in Canada.A
Printing InformationiERP # 125109Size: 3¾ x 5½ inchesStock: 80 lb cougar cover card stockPrint Color: BlackLanguage: English
DAILY BUMP TEST iERP: 125538BW recommends to “bump test” the sensor(s), before each day’s use to confi rm their ability to respond to gas by expos-in
GasAlertMicroClip User Manual iv
List of Figures Figure Title Page 1. GasAlertMicroClip Detector...
GasAlertMicroClip User Manual vi CAUTION: FOR SAFETY REASONS, THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UND
GasAlertMicroClip Introduction a Warning To ensure your personal safety, read “Safety Information” before you use the detector. The GasAlertMicroCli