GasAlertMicroClip XT
User Options
IntelliFlash
When enabled, the green LED flashes to provide continuous visual con-
firmation that the detector is operating correctly.
Note
IntelliFlash is only applicable to GasAlertMicroClip XT.
IntelliFlash automatically deactivates during a low battery
alarm, a self-test fail, a calibration fail, a bump test fail, or dur-
ing an alarm event.
To define how often IntelliFlash occurs (1-60 seconds), refer to Confi-
dence Beep and IntelliFlash Interval. Default interval is 1 second.
The detector is shipped with IntelliFlash enabled.
Latching Alarms
When enabled, a low alarm persists until the alarm is acknowledged
and gas concentrations are below the low alarm setpoint. The audible
alarm can be temporarily deactivated by pressing C, but the LCD con-
tinues to display the peak concentration values until the alarm condition
no longer exists.
The detector is shipped with Latching Alarms disabled.
Low Alarm Acknowledge
When enabled, the audible alarm can be deactivated during a low alarm
for the CO, H
2
S, and LEL sensors. The LED and visual alarm indicators
remain active until the alarm condition changes or the detector deacti-
vates.
Press C to acknowledge the low alarm and deactivate the audible
alarm.
Note
Low Alarm Acknowledge is not applicable to O
2
.
The detector is shipped with Low Alarm Acknowledge disabled.
Safe Mode
When enabled, SAFE displays continuously on the LCD unless an alarm
condition occurs. Safe Mode provides visual confirmation that no (moni-
tored) hazardous gas is present.
The detector is shipped with Safe Mode disabled.